23.2.2. Settings of Groups A - F
Service operation methods of Groups
G R O U P – A S E T T I N G |
|
N O R M A L R E C S E T T I N G |
|
A L A R M E V E N T R E C S E T T I N G |
|
A L A R M E V E N T R E C M O D E | S E Q U E N C E |
A L A R M I N P U T M O D E | E D G E |
P O S T A L A R M T I M E | 9 9 9 S E C |
M O T I O N D E T E C T M O D E | L E V E L |
P O S T M O T I O N T I M E | 1 S E C |
Item |
| Selection | Description |
| |||||
|
|
|
|
|
|
|
|
| |
NOMAL REC SETTING |
|
|
|
|
|
|
| For setting, refer to p. 81; Normal recording setting. | |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| |
ALARM EVENT |
|
|
|
|
|
|
| For setting, refer to p. 82; Alarm event recording setting. | |
REC SETTING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
ALARM EVENT | SEQUENCE / LAST | Sets the operation of alarm event recording when multiple alarm events | |||||||
REC MODE |
|
|
|
|
|
|
| have occurred. | |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| SEQUENCE: Records all cameras set for alarm event. It is possible to | |
|
|
|
|
|
|
|
|
| set multiple alarm events for each camera, including up to |
|
|
|
|
|
|
|
|
| four alarm inputs and four motion detection settings. *1 *2 |
|
|
|
|
|
|
|
| LAST: | Records only the camera that triggers alarm last. It is possi- |
|
|
|
|
|
|
|
|
| ble to set one alarm input and one motion detection setting |
|
|
|
|
|
|
|
|
| for each camera. *1 |
ALARM INPUT MODE |
| LEVEL / EDGE | Select either "Level" or "Edge" depending on the type of signal input to | ||||||
|
|
|
|
|
|
|
| the Priority Recording Terminal. For information on recording operation | |
|
|
|
|
|
|
|
| when the Level or Edge mode is selected, see " Recording Operation | |
|
|
|
|
|
|
|
| When Edge/Level Settings Are Performed" on page 43. | |
|
|
|
|
|
|
|
|
| |
POST ALARM TIME |
| 0 - 60 - 999 SEC / | Set the length of time an Alarm Event recording is to continue after being | ||||||
|
| NO LIMIT | triggered by an alarm input. | ||||||
|
| 0 - 999 SEC: Recordings are performed during the set post alarm time. | |||||||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| If the alarm input mode is set to "Edge," the post alarm |
|
|
|
|
|
|
|
|
| time can be set to 1 second or more. If it is set to "Level," |
|
|
|
|
|
|
|
|
| it can be set to 0 second or more. *4 |
|
|
|
|
|
|
|
| NO LIMIT: Recordings continue alarm recording completion until | |
|
|
|
|
|
|
|
|
| manually stopped. |
|
|
|
|
|
|
|
|
| |
MOTION DETECT |
| LEVEL / EDGE | Set the Motion Detection mode to either "Level" or "Edge." For information | ||||||
MODE |
|
|
|
|
|
|
| on recording operation when the Level or Edge mode is selected, see | |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| " Recording Operation When Edge/Level Settings Are Performed" on | |
|
|
|
|
|
|
|
| page 43. |
|
|
|
|
|
|
|
|
|
| |
POST MOTION TIME |
| 1 - 60 - 999 SEC / | Set the length of time an Alarm Event recording is to continue after being | ||||||
|
| NO LIMIT | triggered by motion detection. | ||||||
|
|
|
| ||||||
|
|
|
|
|
|
|
| 1 - 999 SEC: Recordings are performed during the set post motion time. *4 | |
|
|
|
|
|
|
|
| NO LIMIT: Recordings continue | |
|
|
|
|
|
|
|
|
| until manually stopped. |
|
|
|
|
|
|
|
|
|
|
Notes |
|
|
|
|
|
|
|
|
|
·Underlined settings represent
·Default settings for Groups A - F are all identical.
*1 Even with the Sequence setting, if alarms are input in order, the last input screen is displayed.
*2 If multiple events are set, the camera with the lowest number is displayed on the full screen on the monitor.
*3 When multiple
*4 If post time is less than the recording rate, the image may not be played back correctly.
80