TOA Electronics C-DR161 CU Series, C-DR091 CU Series operating instructions Stop mode

Models: C-DR161 CU Series C-DR091 CU Series

1 130
Download 130 pages 36.17 Kb
Page 42
Image 42

Recording within a scheduled time period

[ Recording only when Priority recording is initiated or alarm event occurs ]

To stop recording within the scheduled time period, set all cameras to “Recording OFF” in normal recording settings. To perform recording only when Priority recording or Alarm Event recording is initiated, recording is performed as shown in the following figure.

 

 

 

 

 

 

 

 

 

(1)

If the Priority recording's event occurs, Pre-Recording is first

 

 

 

Priority recording

 

 

 

 

 

 

 

 

made, then Priority recording begins.

 

 

 

 

 

 

 

 

 

(2)

When the Priority recording ends, recording reverts to recording

Priority recording

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

stop mode.

 

 

 

start

 

 

 

Start

End

1

 

 

Pre-Alarm

 

2

5

6 (3)

If Alarm Event recording is initiated, Pre-Recording is first made,

 

 

recording

 

 

 

 

 

 

 

End

 

 

 

then Alarm Event recording begins.

 

Pre-Alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

recording start

 

 

 

 

 

(4)

When the preset Alarm Event recording interval elapses, recording

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

reverts to recording stop mode.

 

 

 

Recording stop

 

 

 

 

 

 

 

 

 

 

(5) Priority recording is initiated if a Priority signal is received or if

Pre-Alarmmanually started during Alarm Event recording.

recording start

 

 

 

(6) When the Priority recording ends, recording reverts to Normal

3

Pre-Alarm

4

recording

recording.

Alarm event

 

End

 

 

 

 

 

start

 

 

 

Alarm event recording

Alarm input recording Motion-detected recording

Notes

Even if Priority recording or Alarm recording is initiated, it is made following Pre-Recording.

Pre-Recording is initiated when the Pre-Alarm interval is set to 1 second or more.

Recording outside scheduled time periods

[ Recording only when Priority recording is initiated ]

Recording is performed as follows outside the scheduled time period.

Priority recording

 

 

 

 

 

 

 

Priority recording

 

 

 

 

 

 

 

 

start

 

 

 

 

 

 

 

 

 

 

1

 

 

Pre-Alarm

 

2

 

 

recording

 

 

Pre-Alarm

 

 

End

 

 

 

 

recording start

 

 

 

 

 

 

 

 

 

 

Recording stop

(1)When the Priority recording's event occurs, Pre-Recording is first made, then Priority recording begins.

(2)When the preset Priority recording interval elapses, recording reverts to recording stop mode.

Notes

Normal recording and Alarm event recording cannot be performed.

If Priority recording is initiated, Pre-Recording is first made, then Priority recording begins.

Pre-Recording is initiated when the Pre-Alarm interval is set to 1 second or more.

42

Page 42
Image 42
TOA Electronics C-DR161 CU Series, C-DR091 CU Series operating instructions Stop mode