23.1. Priority recording setting

Priority recording is given higher priority over Auto-recording. Use this recording mode to check recording details when, for example, a suspicious person intrudes or when making recording outside the scheduled time period. (Refer to p. 39; Priority recording.)

P R I O R I T Y R E C S E T T I N G

 

R E C S E T T I N G

 

 

P R I O R I T Y R E C I N P U T M O D E

L E V E L

A U D I O

O N

P O S T T I M E

1 1 1 S E C

Item

Selection

Description

 

 

 

 

 

 

 

 

REC SETTING

 

 

 

 

 

 

Refer to p. 78; Recording Setting for setting selections.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRIORITY REC

LEVEL / EDGE

Set either "Level" or "Edge" depending on the type of signal input to the Priority

INPUT MODE

 

 

 

 

 

 

Recording Input Terminal.

 

 

 

 

 

 

 

For information on recording operation when the Level or Edge mode is selected,

 

 

 

 

 

 

 

see " Recording Operation When Edge/Level Settings Are Performed" on page 43.

 

 

 

 

 

 

 

 

AUDIO

ON / OFF

ON: Audio is also simultaneously recorded for the duration of Priority Recording.

 

 

 

 

 

 

 

OFF: No audio is recorded.

 

 

 

 

 

 

 

 

POST TIME

0 - (60) - 999 SEC

Set the length of time after which Priority Recording will finish.

 

 

 

 

 

 

 

0-999 SEC : Records for a set period of post-alarm time. This must be

 

/ NO LIMIT

 

1 second or more if the Priority Recording mode is set to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"Edge," but can be set to 0 or more if this mode is set to "Level."

 

 

 

 

 

 

 

NO LIMIT : Priority recording continues until stopped manually.

 

 

 

 

 

 

 

 

Note: Underlined settings represent factory-preset settings.

*1 If the Priority Recording mode is set to "Level," recording initiated by the Digital Video Recorder or remote controller Priority Rec key will continue until stopped manually.

77

Page 77
Image 77