5.RFID ANALYZE TOOL

EO13-33002

(Revision Date: Mar. 26, 2009)

5.4 Operatin Procedure

RFID tag type to be analyzed (Tag type)

Selectable tag types are different depending on the RFID module types.

RFID module type

U1: B-9704-RFID-U1-US/EU

H1: B-9704-RFID-H1-QM

U2: B-SA704-RFID-U2-EU/AU/US/CN-R B-SX708-RFID-U2-EU/CN-R

Tag type

ISO18000-6B (U1), EPC Class1 (U1), EPC C1 Gen2 (U1).

C220 (H1), I-Code (H1), ISO15693 (H1), Tag-it (H1) and C320 (H1) EPC C1 Gen2

Tag Type

Tag Data

Tag Data

Data to be written onto a tag is entered.

Data is different for each tag type. Please note the Analyze Tool program does not check the data to be written on to a tag.

NOTE: When the U2 type module tries to write same data that has already been written onto the same tag, a data write operation is not performed and results in OK. To properly perform a write test on the U2 type module, entered data to be written is automatically changed each time of a retry, by rotating the data in units of 2 digits.

Example) 1st try: 123456789012 2nd try: 345678901212 3rd try: 567890121234 …