2. SYSTEM MODE

EO13-33002

2.2 Parameter Setting

2.2.6 Parity Selection

This parameter is to choose the parity of the RS-232C interface.

When “<2>PARAMETER SET” appears, press the [PAUSE] key until the following display appears.

<2>PARAMETER SET PARITY NONE

Use the [FEED] or [RESTART] key to select a desired option.

[RESTART]

[FEED]

PARITY EVEN

PARITY ODD

PARITY NONE

After selecting the parity, press the [PAUSE] key.

2.2.7 Flow Control Code Selection

This parameter is to choose a flow control code of the RS-232C interface.

When “<2>PARAMETER SET” appears, press the [PAUSE] key until the following display appears.

<2>PARAMETER SET XON+READY AUTO

Use the [FEED] or [RESTART] key to select a desired option.

[RESTART]

[FEED]

XON/XOFF AUTO

XON+READY AUTO

READY/BUSY

XON/XOFF

READY/BUSY RTS

XON/XOFF mode

XON/XOFF+READY/BUSY (DTR) mode

READY/BUSY (DTR) mode

XON/XOFF mode

RTS mode

After selecting a flow control code, press the [PAUSE] key.

NOTE: The following is the detailed descriptions for each transmission control code.

1)XON/XOFF AUTO

At the power on time, the printer outputs XON. At the power off time, the printer outputs XOFF.

2)XON+READY AUTO

At the power on time, the printer outputs XON. At the power off time, the printer outputs XOFF.

3)READY/BUSY

At the power on time, the DTR signal output from the printer turns to High level (READY). At the power off time, the printer does not output XOFF.

4)ON/XOFF

At the power on time, the printer outputs XON. At the power off time, the printer does not output XOFF.

5)READY/BUSY RTS

At the power on time, the RTS signal output from the printer turns to High level (READY). At the power off time, the printer does not output XOFF.

2-22