2. SYSTEM MODE

EO13-33002

2.2 Parameter Setting

2.2 Parameter Setting

Outline of Parameter Setting

In the Parameter Setting mode, various kinds of parameters, such as communication, key, LCD, etc. can be set. This will allow a use of the printer to comply with your operating conditions.

The Parameter Setting menu contains the following:

<2>PARAMETER SET

[PAUSE]

<2>PARAMETER SET FONT CODE PC-850

[PAUSE]

<2>PARAMETER SET ZERO FONT 0

[PAUSE]

<2>PARAMETER SET SPEED 9600bps

[PAUSE]

<2>PARAMETER SET DATA LENG. 8bits

[PAUSE]

<2>PARAMETER SET STOP BIT 1bit

[PAUSE]

<2>PARAMETER SET PARITY EVEN

[PAUSE]

<2>PARAMETER SET XON+READY AUTO

[PAUSE]

<2>PARAMETER SET LCD ENGLISH

[PAUSE]

<2>PARAMETER SET FORWARD WAIT OFF

[PAUSE]

<2>PARAMETER SET HEAD UP CUT OFF

[PAUSE]

<2>PARAMETER SET RBN SAVE ON (TAG)

[PAUSE]

<2>PARAMETER SET CODE ESC,LF,NUL

[PAUSE]

<2>PARAMETER SET RIBBON NON TRANS

[PAUSE]

<2>PARAMETER SET PEEL OFF STS OFF

[PAUSE]

Character code selection

Character zero selection

Baud rate selection

Data length selection

Stop bit length selection

Parity selection

Flow control code selection

LCD language selection

Auto forward wait selection

Head up cut selection

Ribbon save function selection

Control code selection

Ribbon type selection

Strip wait status selection

<2>PARAMETER SET FEED KEY FEED

[PAUSE]

<2>PARAMETER SET KANJI CODE TYPE1

[PAUSE]

<2>PARAMETER SET EURO CODE B0

[PAUSE]

<2>PARAMETER SET AUTO HD CHK OFF

[PAUSE]

<2>PARAMETER SET ACK/BUSY TYPE1

[PAUSE]

<2>PARAMETER SET WEB PRINTER OFF

[PAUSE]

<2>PARAMETER SET SENS POSI CENTER

[PAUSE]

<2>PARAMETER SET INPUT PRIME OFF

[PAUSE]

<2>PARAMETER SET EX.I/O TYPE1

[PAUSE]

<2>PARAMETER SET PLUG & PLAY OFF

[PAUSE]

<2>PARAMETER SET LBL/RBN END TYPE1

[PAUSE]

<2>PARAMETER SET PRE PEEL OFF OFF

[PAUSE]

<2>PARAMETER SET BACK SPEED STD

[PAUSE]

<2>PARAMETER SET MAXI CODE TYPE1

[PAUSE]

<2>PARAMETER SET PEEL OFF TRQ R0

[PAUSE]

<2>PARAMETER SET STABILIZER ON

[PAUSE]

Feed key function selection

Kanji code selection

Euro code selection

Auto print head check selection

Centronics ACK/BUSY timing selection

Web printer function selection

Media sensor selection

Input prime selection

Expansion I/O interface type selection

Plug & Play selection

Label end/Ribbon end selection

Pre-strip selection

Reverse feed speed selection

Maxi code specification selection

Strip motor torque selection

Stabilizer function selection

NOTE: Baud rate, Data length, Parity, and Transmission control code should be set to the same values as those of the host computer. Failure to do this causes improper operation.

2-18

Page 24
Image 24
Toshiba B-SX6T, B-SX8T manual Outline of Parameter Setting