2. SYSTEM MODE

EO13-33002

2.5 Sensor Adjustment

2.5 Sensor Adjustment

Outline of the Sensor Adjustment

In the Sensor Adjustment mode, the status of the sensors and thermistors is displayed. Also you can store media level voltage and media end level voltage for the Black Mark, Feed Gap, and Ribbon End Sensors.

The Sensor Adjustment menu contains the following:

<5>SENSOR ADJ.

[PAUSE]

<5>SENSOR ADJ. [H]28°C [A]28°C

[PAUSE]

<5>SENSOR ADJ. [REFLECT] 3.5V

[FEED] or [RESTART]

<5>SENSOR ADJ. [REFLECT] 4.8V*

[PAUSE]

Thermistor Status Display:

Temperatures being detected by the Print Head Thermistor and the Ambient Thermistor are displayed

Black Mark Sensor Status Display:

Voltage being detected by the Black Mark Sensor is displayed

Black Mark Sensor Adjustment:

Using the media actually used, a “media level” voltage is stored.

<5>SENSOR ADJ. [TRANS.] 2.4V

[FEED] or [RESTART]

Feed Gap Sensor Status Display:

Voltage being detected by the Feed Gap Sensor is displayed.

<5>SENSOR ADJ. [TRANS.] 4.1V*

[PAUSE]

Feed Gap Sensor Adjustment:

Using the media actually used, a “media level” voltage is stored.

<5>SENSOR ADJ. [PE]R0.1V T4.8V

[FEED] or [RESTART]

<5>SENSOR ADJ. [PE]R0.1V T4.8V*

[PAUSE]

<5>SENSOR ADJ. [RIBBON] 3.1V

[FEED] or [RESTART]

Black Mark Sensor/Feed Gap Sensor Status Display (No media):

“No media level” voltage detected by the Black Mark Sensor/Feed Gap Sensor is displayed.

Black Mark Sensor/Feed Gap Sensor Adjustment (No media): “No media level” voltage is stored.

Ribbon End Sensor Status Display:

Voltage being detected by the Ribbon End Sensor is displayed.

<5>SENSOR ADJ. [RIBBON] 3.1V*

[PAUSE]

Ribbon End Sensor Adjustment:

Using the ribbon actually used, a “ribbon level” voltage is stored.

NOTES: 1. Perform a sensor threshold setting after changing the media to a different type.

2.An error related to the print position may be caused by the improperly set sensor threshold. In this case please perform a threshold setting in this mode. In case further adjustment is required, refer to Section 2.3 Printer Parameter Fine Adjustment to make the threshold fine adjustment.

3.When pressing the [FEED] and [RESTART] keys at the same time in the Sensor Adjustment menu, the display returns to “<5>SENSOR ADJ.”.

4.The sensor status is checked every 200 msec. Therefore, the display may change according to the status.

2-58