2. SYSTEM MODE

EO13-33002

2.2 Parameter Setting

2.2.22 Input Prime Selection

This parameter is to choose whether to enable a reset operation when INIT signal is ON.

Normally, when the printer receives a reset request signal (nInit signal) from the host via Centronics interface, the printer will be reset and turn to the idle state.

When the INPUT PRIME parameter is set to OFF, the printer is reset but does not turn to idle. When this parameter is set to ON, the host sends an INIT signal and the printer turns to idle each time the printer is turned on. If you would like to avoid this processing, set this parameter to OFF.

When “<2>PARAMETER SET” appears, press the [PAUSE] key until the following display appears.

<2>PARAMETER SET INPUT PRIME OFF

Use the [FEED] or [RESTART] key to select a desired option.

[RESTART]

[FEED]

INPUT PRIME OFF

INPUT PRIME ON

Unavailable

Available

After selecting the Input Prime, press the [PAUSE] key.

2.2.23 Expansion I/O Interface Type Selection

This parameter is to choose a type of the Expansion I/O interface operating mode.

This parameter should be set depending on the expansion I/O control specification of the device to be connected via the expansion I/O interface. For details, refer to the External Equipment Interface Specification.

When “<2>PARAMETER SET” appears, press the [PAUSE] key until the following display appears.

<2>PARAMETER SET EX.I/O TYPE1

Use the [FEED] or [RESTART] key to select a desired option.

[RESTART]

[FEED]

EX.I/O TYPE1

EX.I/O TYPE2

TYPE1: Standard mode

TYPE2: Inline mode

After selecting an Expansion I/O Interface type, press the [PAUSE] key.

2-30

Page 36
Image 36
Toshiba B-SX6T, B-SX8T manual Input Prime Selection, Expansion I/O Interface Type Selection