2. SYSTEM MODE

EO13-33002

(Revision Date: Jul. 24, 2008)

2.1 Self-diagnostic Test

• Descriptions of the Maintenance Counter

#

Item

Count Condition

Range

(1)

Total media distance

Counts when the feed motor is driven to feed, print or issue media.

0.0 to 3200.0 km

 

covered

(Counted also during a reverse feed.) See NOTE 2.

 

(2)

Media distance

Destination printed on the same line indicates one selected for a

0.0 to 3200.0 km

 

covered

parameter clear.

 

(3)

Print distance

Counts while printing. (Reverse feed is not counted.) See NOTE 3.

0.0 to 200.0 km

(4)

Cut count

Counts every cut. See NOTE 4.

0 to 1000000 times

(5)

Head up and down

Counts every head up and down cycle by means of the solenoid which

0 to 2000000 times

 

cycle count

is used for the ribbon save function. See NOTE 4.

 

(6)

Ribbon motor driving

Counts when the ribbon motor is driven to feed, print or issue media.

0 to 2000 hours

 

time

(The driving time is also counted during a reverse feed.) See NOTE 5.

 

(7)

Solenoid drive time for

Counts when the ribbon save function is activated. See NOTE 5.

0 to 1000 hours

 

head up

 

 

(8)

RS-232C hardware

Counts when a parity, overrun or framing error occurs. See NOTE 6.

0 to 255 times

 

error count

 

 

(9)

System error count

Counts when a system error occurs.

0 to 15 times

(10)

Momentary power

Counts when a momentary power interruption occurs.

0 to 15 times

 

failure count

 

 

(80)

Number of successful

Counts when an RFID write has succeeded.

0 to 9999999 times

 

RFID write

 

 

(81)

Number of failure in

Counts when an RFID write has failed.

0 to 9999999 times

 

RFID write

 

 

NOTES:

1.Item from (2) through (10) are initialized to “0” after RAM clear.

2.If the media distance covered is 50.0 cm or less, it is rounded down and no data is added to the memory at power off.

3.If the print distance is 5.5 m or less, it is rounded down and no data is added to the memory at power off.

4.If the count is 31 or less, it is rounded down and no data is added to the memory at power off.

5.If the driving time is 27 sec. or less, it is rounded down and no data is added to the memory at power off.

6.When a sent command results in an error, the same number as the data capacity of the command is counted by byte.

2- 7

Page 13
Image 13
Toshiba B-SX8T, B-SX6T manual Descriptions of the Maintenance Counter