2.9 RFID Module Setting

2.9.13 RFID Module Q Value Setting

This parameter is to set the Q value.

In the case multiple RFID tags are read at the same time, this menu is useful to pinpoint a target tag.

Set the Q value to “1” or greater (2 is recommended.) with the [FEED] or [RESTART] key. Q value “0” causes the tags to interfere with each other and disables proper data write.

When a Q value is set, set an AGC threshold for data write and an AGC threshold lower limit for retry, also. Setting all these values enable writing data to a tag placed just above the antenna. (For details, refer to Section 8.5 of Option Installation Manual) The factory default is 0.

When “Q VALUE” is displayed, press the [PAUSE] key.

<10>RFID

 

Q VALUE

2

Use the [FEED] or [RESTART] key to select a desired option. (Range: 0 to 15)

[RESTART]

[FEED]

QVALUE 15

QVALUE 14

QVALUE 1

QVALUE 0

After selecting the adjustment value, press the [PAUSE] key.

2-84