5.RFID ANALYZE TOOL

EO13-33002

(Revision Date: Jul. 24, 2008)

5.4 Operatin Procedure

Feed amount range (Front/Back Feed)

Set the feed amount range where an RFID tag is analyzed.

Upper limit (Reverse feed amount): 0 – 9990 (in units of 0.1 mm)

Lower limit (Forward feed amount): 0 – 9990 (in units of 0.1 mm)

The values can be entered by either pressing the “UP” or “DOWN” button or directly entering a number. While the printer feeds RFID tag media in the specified range, it stops feeding at 3-mm intervals and analyzes the read/write performance of tag.

The number of read/write times (Try)

Enter the number of times a data read/write is performed at each analysis position (1 – 255).

Reverse feed amount

Forward feed amount

Try: 1 – 255

[STOP] button

[End] button

5- 18