2. SYSTEM MODE

EO13-33002

(Revision Date: May 22, 2007)

2.6 RAM Clear

2.6.1 RAM Clear Menu Selection

When “<6>RAM CLEAR” appears, press the [PAUSE] key.

Choose a RAM Clear menu among “No RAM Clear”, “Maintenance Counter Clear”, or “Parameter Clear”.

[RESTART]

[FEED]

NO RAM CLEAR

MAINTE.CNT CLEAR

PARAMETER CLEAR

RAM Clear is not performed.

Clears the Maintenance Counter.

Clears the Parameter.

NOTES: 1. To exit the RAM clear menu selection, press the [FEED] and [RESTART] keys at the same. The display returns to “<6>RAM CLEAR”.

2.Even after performing a RAM clear, the following items are still stored: Label distance covered, Sensor adjustment value, IP address, Socket port number, Language for the LCD message, data in the flash memory.

2.6.2No RAM Clear

NO RAM CLEAR

Press the [PAUSE] key. No RAM Clear operation is performed and the display returns to “<6>RAM CLEAR”.

Pressing the [PAUSE] key again causes the display to return to “NO RAM CLEAR”.

2.6.3 Maintenance Counter Clear

B-SX6T-TS12-QM-R and B-SX8T-TS12-QM-R (V1.0B or earlier)

MAINTE.CNT CLEAR

All items of the Maintenance Counter are cleared.

Press the [PAUSE] key to perform the Maintenance Counter Clear.

When the Maintenance Counter Clear is completed, the following message appears.

*** COMPLETE ***

Turn off the printer to exit this mode.

B-SX8T-TS12-QM-R (V1.1 or greater)

Choose a maintenance counter clear mode with the [FEED] or [RESTART] key.

MAINTE.CNT CLEAR

[PAUSE]

ALL CLEAR

[FEED] [RESTART]

All clear mode: All items of the Maintenance Counter are cleared.

FEED&PRINT CLEAR

[FEED] [RESTART]

CUT CLEAR

[FEED] [RESTART]

Feed & Print clear mode: Only the label distance covered and the Print distance are cleared.

Cut clear mode: Only the cut count is cleared.

After choosing a mode, press the [PAUSE] key. A maintenance counter clear will be performed according to the chosen mode.

2-62

Page 68
Image 68
Toshiba B-SX6T, B-SX8T RAM Clear Menu Selection, No RAM Clear, Maintenance Counter Clear, SX8T-TS12-QM-R V1.1 or greater