5.RFID ANALYZE TOOL

EO13-33002

(Revision Date: Jul. 24, 2008)

5.4 Operatin Procedure

4.When the “CommSetting” screen appears, perform the serial port or LAN setting in accordance with the settings of the B-SX6T/SX8T printer.

Port: COM1 to COM9

Baudrate: 2400, 4800, 9600, 19200, 38400, 115200

Data bit: 8 bit

Parity: NONE, EVEN, ODD

Stop bit: 1, 2

Flow control: NON, XON, XON/XOFF,

RTS/CTS+XON/XOFF

Printer IP Address

Socket Port No.

NOTES:

1.Choose the port to which the printer is connected.

2.Choose “NON” for the Flow control of the RFID Analyze Tool. However, any flow control code of the printer is acceptable.

3.The data bit for the Analyze Tool is fixed to 8. Make sure that the data length for the printer is set to 8 bits.

4.The command flame for the Analyze Tool is “{ }”. Make sure that the control code for the printer is set to “AUTO” or “{ }”.

5.When the printer and the PC are connected via LAN, a printer IP address and socket port number need to be entered.

Default Printer IP Address: 192.168.10.20, Socket Port No.: 8000

5- 15