2. SYSTEM MODE

EO13-33002

2.3 Printer Parameter Fine Adjustment

• Example of X Coordinate Fine Adjustment

When setting –50.0 mm

Compared with “+0.0mm” position, the print position is shifted to the left.

When setting +0.0 mm

When setting +50.0 mm

Compared with “+0.0mm” position, the print position is shifted to the right.

Feed Direction

Top Down Printing X

Y

ABC

50.0mmX

ABC

50.0mm

Y

Bottom First Printing

ABC

NOTES:

1.The X coordinate fine adjustment is performed to fine adjust the print position in horizontal direction (left or right).

2.Adjust the X coordinate within the effective print range. After the value reaches the coordinate 0, the value remains unchanged even if the subsequent fine adjustment is performed in the negative direction.

3.This adjustment cannot be used in the Self Test mode or Test print.

4.The fine adjustment value equals to the sum of the fine adjustment values set by the PC command and this parameter. The maximum X coordinate fine adjustment value is +99.9 mm. When the value reached the maximum, the value remains unchanged even if the subsequent fine adjustment is performed.

2-43

Page 49
Image 49
Toshiba B-SX8T, B-SX6T manual Example of X Coordinate Fine Adjustment