3.8 USB Floppy Disk TestUSB Floppy Disk Test

3 Tests and Diagnostics

Subtest 01 Sequential Read

This subtest performs a Cyclic Redundancy Check (CRC) that continuously reads all the tracks (track: 0 to 39/0 to 79) on a floppy disk.

The start track is specified at the start of the FDD test. Refer to 2.in this chapter.

Subtest 02 Sequential Read/Write

This subtest continuously writes data pattern B5ADADh to all the tracks (track: 0 to 39/0 to 79) on a floppy disk. The data is then read and compared to the original data.

Subtest 03 Random Address/Data

This subtest writes random data to random addresses on all tracks (track: 0 to 39/0 to 79) on a floppy disk. The data is then read and compared to the original data.

Subtest 04 Write Specified Address

This subtest writes the data specified by an operator to a specified track, head, and address.

Subtest 05 Read Specified Address

This subtest reads data from a track, head, and address specified by an operator.