2 Troubleshooting | 2.4 System board Troubleshooting |
Table 2-3 D port status (6/6)
D port status
Inspection items
details
F11Dh |
| Canceling NMI mask |
|
|
|
|
| Examining the checksum of TIT |
|
|
|
|
| Clearing IRT running flag for runtime |
|
|
|
|
| Update checksum for runtime |
|
|
|
|
| Checking whether a CPU, an HDD or other component |
|
| have been upgraded |
|
| Disabling a PC Card that is not being used |
|
|
|
| Initializing HW just before | Setting up battery safe mode |
| BOOT and waiting for the |
|
| Setting up date | |
| completion | |
|
| |
|
| Waiting for the end of |
|
|
|
|
| Updating DMI Wakeup factor and |
|
| table |
|
| Closing configuration space of PCI devices |
|
|
|
|
| Cache control |
|
|
|
| Treating | Updating parameter block A |
|
|
|
|
| Setting up the clock speed of the CPU to the appointed |
|
| value by the Setup |
|
| Waiting for the motor off of a disabled HDD |
|
|
|
| Treating after | Clearing power button status |
| PRE_BOOT_SETUP |
|
| Enabling the power button | |
|
| |
|
|
|
FFFFh | Completion | Completion of checking DPORT status |
|
|
|
Check 1 If the D port status error code F11Ah is displayed, go to the 3.5” USB FDD Troubleshooting Procedures in Section 2.5 or the 1.8” HDD Troubleshooting Procedures in Section 2.6.
Check 2 If any other D port status error code is displayed, perform Procedure 3.
D port error statuses are following:
Error code | Contents |
|
|
F160h | Timer CH2 error |
|
|
F161h | PIT error |
|
|
F162h | PIC #1 error |
|
|
F163h | PIC #2 error |
|
|
F11Eh | Clock generator setting error |
|
|
PPORTEGE R100 Maintenance Manual |