3 Tests and Diagnostics | 3.12 Expansion Test |
3.12 Expansion Test
To execute the expansion test, select
NOTE: To execute this subtest, the PC card wraparound connector is required.
Subtest 01 PCMCIA Wraparound
This test checks the following signal line of the PC card slot:
Address line
REG#, CE#1, CE#2 line
Data line
Speaker line
Wait line
BSY#, BVD1 line
This subtest is executed in the following order:
Sub# | Address | Good | Bad | Contents |
|
|
|
|
|
01 | 00001 | nn | xx | Address line |
| 00001 | nn | xx | REG#, CE#1, CE#2 |
|
|
|
| nn=A0, 90, 80, 00 |
02 | 00002 | ww | rr | Data line |
|
|
|
| ww=write data, rr=read data |
03 | 00003 | Speaker line | ||
|
|
|
|
|
04 | 00004 | 40,80 | xx | Wait line (40<xx<80) |
|
|
|
|
|
05 | 00005 | nn | xx | Other lines (BSY#, BVD1) |
|
|
|
| NN=21, 00 |
NOTE: When selecting the subtest number 01, the following message will appear. Specify the slot you want to use.
Test slot number select (1:slot0, 2:slot1, 0:slot0&1)?
Select the number.
PORTEGE R100 Maintenance Manual |