4.30 LCD unit/FL inverter4 Replacement Procedures

Installing the LCD unit/FL inverter

To install the LCD unit/FL inverter, follow the steps below and refer to Figure 4-55 to 4-59

1. Place the LCD unit in place and secure it with the following screws.

• M2.0⋅3C

BIND screw

⋅4

2.Connect the LCD harness to the connector on the LCD unit and stick two glass tapes in place.

3.Connect the LCD harness and HV harness to the connectors on the both sides of the FL inverter and set the FL inverter in place.

4.Stick the glass tape in place.

5.Set the LCD cover to the cover assembly while engaging the latches.

6.Secure the LCD unit with the following screws.

• M2.5⋅5B

FLAT HEAD screw

⋅2

7.Stick four LCD mask seals (two long seals and two short seals) in place.

8.Arrange the wireless LAN antenna cables and camera harness in place.