Alarms
Avaya Wireless AP-4/ 5/6 User’s Guide 4-111
Setting Syslog Event Notifications
Syslog Events are logged according to the level of detail specified by the
administrator. Logging only urgent system messages will create a far
smaller, more easily read log then a log of every event the system
encounters. Determine which events to log by selecting a priority defined
by the following scale:
Event Priority Description
LOG_EMERG 0 system is unusable
LOG_ALERT 1 action must be taken immediately
LOG_CRIT 2 critical conditions
LOG_ERR 3 error conditions
LOG_WARNING 4 warning conditions
LOG_NOTICE 5 normal but significant condition
LOG_INFO 6 informational
LOG_DEBUG 7 debug-level messages