Serial Upgrade Method

TXD and RXD should be green. They will flash if Enter is pressed.

Figure C-2.Flash Loader Status Lights, Normal Condition

c.Press Enter a few times to display the system prompt “#” on screen.

d.If the prompt does not appear, continue with step 10 (troubleshooting).

e.If the prompt appears, continue with step 11 (uploading files).

10.To troubleshoot the serial connection:

a.If the DCD and CTS status lights are green, re-check the communication settings in the loader, and verify that the COM port and Baud Rate settings are correct.

b.To verify PresentationPRO-II communication settings, on the front panel of the PresentationPRO-II unit press {HOME} > {SYSTEM} > {CONSOLE} to display the Console Port Setup Menu.

 

 

CONSOLE PORT SETUP

 

H

Baud Rate

115200

 

O

N

M

 

 

 

 

A

E

 

 

Data Bits

8

V

 

B

Parity

NONE

 

A

Stop Bits

1

 

C

 

K

 

 

 

 

 

 

A

 

 

 

D

 

 

 

J

Figure C-3.Console Port Setup Menu (sample)

c.On the menu, ensure that the following settings are selected:

Baud Rate = 115200

Data Bits = 8

Parity = NONE

Stop Bits = 1

d.Repeat steps 7 and 8 above, then re-check the status lights.

e.With communication status OK, continue with step 11.

11.To upload files to the PresentationPRO-II unit, click the "Open script file to read and upload" button.

12.In the dialog, select "Upload_All.sld" and click Open. The PresentationPRO-II unit should immediately display the "System in LOADER MODE" message.