`K==réÖê~ÇáåÖ=pçÑíï~êÉ

Ethernet Upgrade Method

23.Click Communication > Ethernet > Connect to display the Ethernet Connection dialog.

Figure C-9.Ethernet Connection Dialog (sample)

Note

If the Ethernet menu pick is grayed out, set the COM port to

None.

24.In the dialog, enter the IP address of the PresentationPRO-II: 192.168.0.10. The default port number is 3000.

25.Click the Connect button. If the connection is successfully established, the message “Connect via Ethernet successful” will be shown in the Status Bar. If you cannot connect, refer to the “Troubleshooting Ethernet Communications” section on page 145 for instructions.

26.To upload files to the PresentationPRO-II unit, click the "Open script file to read and upload" button.

27.In the dialog, select "Upload_All.sld" and click Open. The flash loader echoes commands while the flash is being loaded.

28.It takes approximately three minutes to load the flash memory using the Ethernet method. When complete, the Flash Loader utility displays the “Upload Complete” message. Click OK to continue.

29.Cycle power on the PresentationPRO-II unit, and exit the Flash Loader utility.

30.On PresentationPRO-II, perform a factory reset:

Warning

Use caution when performing this step, as all saved files and saved still frames will be erased.

a.From the Home Menu, press {SYSTEM} to access the System Menu.

b.From the System Menu, press {RESET} to display the Reset Menu.

c.On the Reset Type line, select FACTORY.

d.Press {RESET}. When the confirmation screen appears, press {YES} to reset the system to factory default values.

31.On PresentationPRO-II, verify that the new software has been loaded correctly:

a.From the Home Menu, press {SYSTEM} to access the System Menu.

b.From the System Menu, press {SW VER} to display the Software Version Menu, then verify the new version.

144

 

PresentationPRO-II • User’s Guide

 

Page 156
Image 156
Barco 26-0405000-00 manual None, Figure C-9.Ethernet Connection Dialog sample