qêçìÄäÉëÜççíáåÖ=bíÜÉêåÉí=`çããìåáÅ~íáçåë

`K==réÖê~ÇáåÖ=pçÑíï~êÉ

Ethernet Upgrade Method

qêçìÄäÉëÜççíáåÖ=bíÜÉêåÉí=`çããìåáÅ~íáçåë

„Use the following steps to determine the IP address of the PresentationPRO-II, and establish proper communications:

1.The default IP address for the PresentationPRO-II unit is 192.168.0.10. To verify that this is the correct address, open the terminal program and create a serial communication link to the PresentationPRO-II:

a.Click Start > Programs > Accessories > Communications > HyperTerminal to launch the HyperTerminal application.

b.In the Connection Description dialog, enter a connection name, choose an icon, and click OK.

c.In the Connect To dialog, click the Connect using pull-down menu, and choose COM 1.

d.Click OK to display the COM 1 Properties dialog.

e.Select the following settings:

Baud Rate = 115200

Data Bits = 8

Parity = NONE

Stop Bits = 1

Flow Control = hardware/software

2.Turn on the PresentationPRO-II.

3.In the terminal window, type:

IPINFO

(or SET if in the loader)

4.Verify that the following message is displayed:

#ipinfo Server running

IP Address 192.168.0.10 Listen Port 3000

Subnet Mask 255.255.255.0

DHCP CLIENT

DHCP Srvr IP Addr 192.168.0.11 DHCP Srvr IP Count 180 Static IP Address 192.168.0.10

Note

The exact static IP Address may differ.

5.Ensure that Ethernet is connected from the PC to the hub (to which PresentationPRO-II is connected).

6.Open a DOS command window on the PC:

a.Click Start > Run to display the Run Dialog.

b.In the Open field, type cmd, then click OK to open a DOS command window.