Installation Manual for DiBos Video System

Connections (continued)

Relay output

J1 to J8

Position 1

–2

Relay contact

 

 

N/O contact

 

 

 

Position 2

–3

Relay contact

 

 

N/C contact

 

 

 

Position 4

–5

Common

 

 

 

Position 5

– 6

not occupied

 

 

 

Video input termination

S1, S2

off

Input not

 

terminated

 

 

on

Terminated with

 

75 Ohm (deliv-

 

ery state)

 

 

Alarm input connection:

J9/J11

5 V

Alarm input x

PIN 10

5 kOhm

TTL

Relay load = 60 V/2 A

Note:

Video input 1 – 16

1 input per B&W and CCVS camera

2 inputs per Y/C camera

610–4.998.137.176