Installation Manual for DiBos Video System

A5/11–2004610–4.998.137.176 – 34 –

Connections (continued)

Method 2:

Problem:

The automatic teller machines (ATMs) are located further away from the video

system. The distance between the video system and interface processor and be-

tween the interface processor and an ATM cannot be less than 15 m.

However, the ATMs are close enough to one another for them all to be connected

to the interface processor so that the distance between the interface processor

and each ATM is less than 15 m.

Solution:

The individual ATMs are linked directly to the interface processor by specific

interfaces. Two OVS are required between the video system and the interface

processor to increase the range.

9–pin connection cable
Order no. 4.998.079.686
(connection 1:1)
9–pin connection cable
Order no. 4.998.079.686
(connection 1:1)

OVS 1

V24
(C3)
OPTO
1
5
9
6

OVS 2

OPTO
9
6
1
5
9 pin 9 pin
max. 1,000 m
For jumpering,
see below
1
2
3
1
2
3
C3:
Pin 2 = transmitter line
Pin 3 = receiver line
J2 J1
Jumpering of OVS 1:
For jumpering,
see below
For assignment of OVS see Section 4.18.1
V24
(C3)

video

system

Interface

processor

ATM1 – ATM4

Connection

principle:

Detailed connection:

OVS Interface
processor
OVS
ATM4
ATM1
max. max. max.
max.
15 m 1000 m 15 m
15 m
video system

COM x

1
2
3
1
2
3
C3:
Pin 2 = receiver line
Pin 3 = transmitter line
J2 J1
Jumpering of OVS 2:
For assignment of OVS see Section 4.18.1
Note:
By changing jumper J1 and J2 in the OVS it is
possible to mix up the transmitter and receiver lines (see above).
I4I3 PCI2I1