Installation Manual for DiBos Video System

Connections (continued)

4.9Connecting the Software Dongle and the Printer

The programs are protected against unauthorized use by a dongle. The system cannot be operated without this dongle. The dongle must be con- nected to the PRN interface (LPT1) on the system board and remains there throughout operation. The dongle must be plugged in before switching the system on.

A printer must be connected via the USB interface so as not to hinder the reading out of program information from the dongle.

4.10Connecting a Fault Indicator

A fault indicator (sounder) can be connected to relay 4 of the 1st MVTitan grabber card (must be activated in the configuration under Hardware/ Connections).

The following events will be signaled by the fault indicator:

DImages may be lost because the alarm archive is full

DThe free disk space is not sufficient for the programmed total size of the archives

DThe camera is not transmitting a video signal

DThe database server could not record all images

DThe grabber process does not answer in the prescribed time (timeout)

DThe programmed holidays/special days are not released in the hard- lock

DThe programming for the serially–connected security system has been deleted by a software update

DSystem overload

DThe directory could not be deleted from the database server

DCannot create and write logbook

DThe images could not be recorded by the database server

DThe backup medium is full

DA timed backup could not be executed because a search macro was not found

DThe programmed number of grabbers does not match the actual hardware configuration

D5% of the hard disk is not free

DThe database server is not started