Programming the foyer card reader MINITER RS 485

Programming is carried out using MINITER RS 485 software. This can be installed on a service laptop or on a video system.

Proceed as follows:

1.Start the programming software and select RS 485 operation.

2.Select the COM port to which the foyer card readers are connected via the “Interface” menu item.

Even if several foyer card readers MINITER RS 485 are to be pro- grammed for the first time, only one foyer card reader should be con- nected during programming. This is because the foyer card reader will assign all the card readers with the same bus address by default.

3.Select the “MINITER Read/Identify Miniter” menu and click “Iden- tification of all activ addresses”.

“Address: 48” and “Protocol: Bosch” is displayed.

4.Select foyer card reader number 48 and confirm your selection with ”OK”.

5.Click “Read Miniter” and enter “Password: 991357”. Confirm with ”OK”.

6.The foyer card reader addresses must be specified as follows: Foyer card reader no. 1 = address 48

Foyer card reader no. 2 = address 49 Foyer card reader no. 3 = address 50 Foyer card reader no. 4 = address 51

For operation, the other parameters must be set as follows:

Door opening time: optional

Door opener with buzzer: optional

Door opener interval tone: optional

Monitoring module: no

Password: 991357

Signal chipcard: no

Send start character: no

Data on display: no

Evaluate track 2: yes

Evaluate track 3 or 1: yes

Open door on fault: no

Protocol: Bosch

Bloc list: optional

Data length track 2: 18 (for credit cards)

Data length track 3/1: 26 (for EC cards)

610–4.998.137.176