Installation Manual for DiBos Video System
A5/11–2004610–4.998.137.176 – 46 –
Connections (continued)

4.17 Connecting AutoDome/SAE–Dome

Connecting AutoDome
RS 232
RS 232/BiPhase
converter
COM x
video system LTC 8780
or
LTC 8786 BiPhase
AutoDome
LTC 8569
or
LTC 8570
LTC matrix
code merger
BiPhase
BiPhase
Note: Additionally a code merger LTC 8569 or LTC 8570 is needed, if a
PTZ shall be controlled from the video system and a Bosch LTC ma-
trix.
Connecting AutoDome via matrix
Allegiant Console cable
LTC8506/00
COM x
Videosystem
LTC 8x00 AutoDome
BiPhase
Console
Port
Hinweis: Valid CCL commands can be configured in the DiBos. Then you can
send these pre–configured commands manually to the Allegiant ma-