Installation Manual for DiBos Video System
Connections (continued)
4.18.8Connecting to BZ 1060 (20 mA) video system
OVS | Range | |
max. 1000 m | ||
9 |
| 5 |
COM x | 6 |
| 1 |
C3 | OPTO |
BZ 1060
|
| ZAB | |
|
| +24V | |
GOM |
| ||
+UV | SDO | SDO | |
SDI– | |||
|
| ||
SDI+ |
|
| |
SDO+ | SDI | SDI | |
|
SDO–
It is preferable to use interfaces 6 through 9, but connection to interfaces 2 through 5 is also possible depending on the project.
Program the appropriate interface to AUX (1200 baud), insert jumpers on SIE (V2, V4) for 20 mA interface.