Installation Manual for DiBos Video System
A5/11–2004610–4.998.137.176 – 33 –
Connections (continued)

4.11 Connecting the ATM via the Interface Processor (Serial)

A maximum of 4 automatic teller machines or three automatic teller ma-
chines and 1 access control system can be connected to the video sys-
tem via an interface processor.
The following ATM interfacing variants are available:
Method 1:
Problem:
The automatic teller machines (ATMs) are not located far from the
video system. The distance between the video system and interface
processor and between the interface processor and an ATM should
be less than 15 m.
Solution:
The individual ATMs are linked directly to the interface processor by
specific interfaces.
The distance between the video system and the interface processor
and the interface processor and the ATMs is max. 15 meters.
Connection
principle:
COM x
video system
Interface processor
Detailed connection:
9–pin connection cable
video system Interface
processor
ATM4
ATM1
max. 15 m
max. 15 m
ATM1 – ATM4
I4I3 PCI2I1