SSI Word Delay Time

To enter Delay values from +32,768 to +65,535 s, use this conversion formula:

Desired Delay Value (in s) - 65536 = Entered Delay Value (in s).

As an example, for a 40 ms delay time, 40000 - 65536 = -25536

Sensor Resolution

To enter Resolution values from +32,768 to +65,535 s, use this conversion formula:

Desired Resolution Value - 65536 = Entered Resolution Value. As an example, for a 40,000 count sensor, 40000 - 65536 = -25536

Sensor Cycle

To enter Cycle values from +32,768 to +65,535, use this conversion formula:

Desired Cycle Value - 65536 = Entered Cycle Value.

As an example, for 50,000 sensor cycle rotations, 50000 - 65536

=-15536

Compare 0,1 Value

To enter Compare values from +2,147,483,647 to +4,294,967,295, use this conversion formula:

Desired Compare Value - 4,294,967,296 = Entered Compare Value.

As an example, for a 3,000,000,000 compare value, 3,000,000,000 - 4,294,967,296 = -1,294,967,296