Dot Hill Systems II 200 FC 4 I/O Controller Module and Battery Module LEDs, Status of battery

Models: II 200 FC

1 210
Download 210 pages 50.54 Kb
Page 105
Image 105
Table 6-4I/O Controller Module and Battery Module LEDs

The I/O controller module LEDs and their color definitions are shown in Table 6-4.

Table 6-4I/O Controller Module and Battery Module LEDs

LED

Purpose

LED Color Definition

 

 

 

Battery

Status of battery

Solid green – Battery charged

 

 

Blinking green – Battery charging

 

 

Solid amber – Battery failed

Activity

Cache

Ethernet link (active controller)

Ethernet link (inactive controller)

Ethernet active

RAID controller

SFP link (L)

SFP speed (S)

I/O activity of host

Off – Not busy (no I/O activity)

and disk ports

Blinking green – Busy (active I/O)

Status of memory

Off – Clean cache

cache

Blinking green – Dirty cache; data is in

 

memory and is not written to disk yet

Status of Ethernet

Solid amber – Active link

link

Off – Inactive connection

Status of Ethernet

Off – Active connection on inactive

link

controller, or inactive connection

Status of Ethernet

Blinking green – Busy

activity

 

Status of controller

Blinking green – Good (primary controller)

on I/O controller

Solid green – Good (secondary controller)

module

Solid amber – Failed RAID controller or I/O

 

module

SFP link status

Solid green – Active good FC Connection

 

Off – Empty or failed FC connection

SFP speed status

Solid green – 2 Gbit

 

Off – 1 Gbit

Chapter 6 Checking LEDs 6-7