No SFPs are plugged into the drive channels. This configuration is appropriate for connecting to up to four hosts or fibre switches, with no connection to expansion units (see Figure 4-19and Figure 4-20).

Host port FC0 Host port FC1

Host port FC4

Host port FC5

Figure 4-19SANnet II 200 FC Array Default Single Controller SFP Placement

H/D/RCC

 

 

Host port FC4

Host port FC0

Host port FC1

Host port FC5

Figure 4-20SANnet II 200 SATA Array Default Single-Controller SFP Placement

Note – The SANnet II 200 SATA SE array configuration does not include SFPs. SFPs must be ordered separately.

In a default SANnet II 200 FC expansion unit, SFPs are initially plugged into the left- most port of the upper I/O expansion module and right-most port of the lower I/O expansion module (see Figure 4-21).

Note – The SANnet II 200 SATA SE array does not support this configuration.