labeled FC0, FC1, FC4, and FC5 to indicate channels 0, 1, 4, and 5. Default configurations do not include an SFP connector in every SFP port. To add or change SFP connectors, see to “Changing Your SFP Configuration” on page
The channels and associated ports for the SANnet II 200 FC, SATA, and SATA SE arrays are summarized in Table
Table
| SANnet II 200 FC | SANnet II 200 SATA | SANnet II 200 SATA SE | |
Item | Array | Array | Array | |
|
|
|
|
|
Total number of | 6 | 8 |
| 6 |
ports |
|
|
|
|
Channel 0 | 1 FC0 host or drive port; | 2 | FC0 dedicated host | 2 FCO dedicated host ports |
| default: host port | ports 3 | * | |
Channel 1 | 1 FC1 host or drive port; | 2 | FC1 dedicated host | 2 FC1 dedicated host ports |
| default: host port | ports 3 | * | |
Channel 2 1 | 1 FC2 dedicated drive | 1 | FC2 dedicated drive | None |
| port | port |
| |
Channel 3 2 | 1 FC3 dedicated drive | 1 | FC3 dedicated drive | None |
| port | port |
| |
Channel 4 | 1 FC4 host or drive port; | 1 | FC4 host or drive port; | 1 FC4 host port |
| default: host port | default: host port |
| |
Channel 5 | 1 FC5 host or drive port; | 1 | FC5 host or drive port; | 1 FC5 host port |
| default: host port | default: host port |
|
1.Channel 2 drive ports connect to drive loop A ports on expansion units.
2.Channel 3 drive ports connect to drive loop B ports on expansion units.
3.Only one host port connection per channel is allowed when connecting to a fabric switch.
4.8.1Drive Port Connectivity in a Dual-Controller Array
Drive channels connect to the internal drives in the array and can also connect to drives in external expansion units. The key difference between the SANnet II 200 FC and SATA array drive channels is the assignment of two ports for each channel:
■The SANnet II 200 FC array has a drive channel assigned to two ports on each I/O controller module. Each drive channel is a pair of ports on a single I/O controller module. In a
■The SANnet II 200 SATA array has a drive channel assigned to one port on each I/O controller module in a