5A

JBOD or expansion unit problem (FC)

Drive light

amber?

No

Replace

Yes drive with known- good drive.

Resolved? No

Yes

End

Switch drive with

known

drive from another

slot.

Is the

drive light

green in new

slot?

Yes

Is the

drive light

green in the original slot?

 

 

Replace drive

No

 

 

again.

 

 

 

 

 

Yes End

I/O expansion

module LED

amber

No

 

 

 

Check event

 

Go to 11B

Yes

 

 

messages in

 

 

 

 

 

 

 

 

firmware or software.

 

 

 

 

 

 

 

 

 

 

 

 

No

Replace chassis.

End

SFP link status amber? 2

No

Yes

Check for proper cabling.1

Resolved?

Yes

End

Replace SFP

with

known good one.

No

No

Resolved?

Yes

End

Replace cable.

Resolved?

Yes

End

 

 

Connect

No

 

to known

 

 

good HBA.

 

 

 

Replace I/O

Resolved? No expansion module.

End

Notes

To check cabling, look for bent pins, loose wires, loose cable shielding, or loose cable casing.

Fibre Channel arrays use SFP connectors to attach the array to hosts and expansion units. Each Fibre Channel I/O expansion module has two SFP ports. These ports are labeled Loop A or Loop B.

Prior to replacing a chassis, try the following:

--Reseat the FRU that is not operating correctly.

--Swap the questionable FRU with a known-good FRU from the same array.

Yes

End

Figure B-4JBOD or Expansion Unit Troubleshooting Flowchart, 1 of 2

Appendix B Using a Standalone JBOD Array (SANnet II 200 FC Array Only) B-15

Page 161
Image 161
Dot Hill Systems II 200 FC service manual Jbod or expansion unit problem FC