For overview information about drive LEDs and how they work, see “Front-Panel LEDs” on page 6-2.

You can check physical drive parameters using the firmware application. From the firmware Main Menu, choose view and edit scsi drives. For more information about the firmware application, refer to the SANnet II Family RAID Firmware User’s Guide.

Caution – When you rotate or replace drives, make sure that:

-All I/O is stopped.

-The “Periodic Drive Check Time” setting in the firmware application is set to disabled (this is the default setting). This prevents automatic drive rebuild, which is not recommended for live systems or troubleshooting.

To disable the Periodic Drive Check Time

1.From the Main Menu, choose view and edit Configuration parameters Drive-side SCSI Parameters Periodic Drive Check Time.

A list of Periodic Drive Check Time intervals is displayed.

2.Select Disable.

A confirmation message is displayed.

3.Choose Yes to confirm.

Caution – To prevent any possible data loss, back up user data to another storage device prior to replacing a disk drive.

The following flowchart provides troubleshooting procedures for the FC drive LEDs.

8-14SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

Page 132
Image 132
Dot Hill Systems II 200 FC service manual