4.2.3SANnet II 200 SATA SE Array Connections

Figure 4-5identifies the hardware connections on the back of a dual-controller SANnet II 200 SATA SE array.

Servers and consoles

Management

console

FC device connections

application/data servers and consoles

Figure 4-5Hardware Connections on the Back of a Dual-Controller SANnet II 200 SATA SE Array

4.3Connecting the Chassis to AC Power Outlets

When you connect the AC power cords, install the two provided cord locks at the same time. The AC cord locks are used to securely fasten the AC cable connectors.

Caution – If the array is connected to AC power sources not within the designated 90–135 or 180–264 VAC range, the unit might be damaged.

Note – To ensure power redundancy, be sure to connect the two power supply modules to two separate circuits (for example, one commercial circuit and one UPS).

To connect the AC power cords, perform the following procedure.

Chapter 4 Connecting Your Array 4-7

Page 55
Image 55
Dot Hill Systems II 200 FC Connecting the Chassis to AC Power Outlets, SANnet II 200 Sata SE Array Connections