Dot Hill Systems II 200 FC service manual Field-Replaceable Units, RAID I/O Controller Modules

Models: II 200 FC

1 210
Download 210 pages 50.54 Kb
Page 28
Image 28

in a JBOD array. For example, “SANnet II 200 D1000” identifies a JBOD array with SES firmware version 1000 and “SANnet II 200F A1000” identifies a SANnet II 200 FC RAID array with firmware version 1000.

For a list of supported racks and cabinets, refer to the SANnet II Family Rack Installation Guide for 2U Arrays.

Reliability, availability, and serviceability (RAS) are supported by:

Redundant components

Notification of failed components

Components that are replaceable while the unit is online

For information about specifications and agency approvals, see “SANnet II 200 FC, SATA, and SATA SE Array Specifications” on page A-1.

1.2Field-Replaceable Units

This section describes the field replaceable units (FRUs) contained in the SANnet II 200 FC, SATA, and SATA SE arrays.

1.2.1RAID I/O Controller Modules

Adual-controller configuration offers increased reliability and availability because it eliminates a single point of failure, the controller. In a dual-controller configuration, if the primary controller fails, the array automatically fails over to the second controller without an interruption of data flow.

The FC, SATA, and SATA SE array I/O controller modules are hot-serviceable. Hot- serviceable means that the module can be replaced while the array and hosts are powered on, but the connected hosts must be inactive.

SANnet II 200 FC array RAID controller modules provide six Fibre Channel ports.

SANnet II 200 SATA array I/O controller modules provide eight Fibre Channel ports.

SANnet II 200 SATA SE array I/O controller modules provide six Fibre Channel ports.

Single- and dual-controller models are available, with the dual-controller version supporting active/passive and active/active configurations. Each RAID controller is configured with 1 Gbyte of cache.

In the unlikely event of an I/O controller module failure, the redundant RAID controller immediately begins servicing all I/O requests. The failure does not affect application programs.

Each RAID I/O controller module can support up to 1 Gbyte of Synchronous Dynamic Random Access Memory (SDRAM) with Error Control Check (ECC) memory. In addition, each controller supports 64 Mbyte of on-board memory. Two Application-

1-8SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

Page 28
Image 28
Dot Hill Systems II 200 FC service manual Field-Replaceable Units, RAID I/O Controller Modules