in a JBOD array. For example, “SANnet II 200 D1000” identifies a JBOD array with SES firmware version 1000 and “SANnet II 200F A1000” identifies a SANnet II 200 FC RAID array with firmware version 1000.
For a list of supported racks and cabinets, refer to the SANnet II Family Rack Installation Guide for 2U Arrays.
Reliability, availability, and serviceability (RAS) are supported by:
■Redundant components
■Notification of failed components
■Components that are replaceable while the unit is online
For information about specifications and agency approvals, see “SANnet II 200 FC, SATA, and SATA SE Array Specifications” on page
1.2Field-Replaceable Units
This section describes the field replaceable units (FRUs) contained in the SANnet II 200 FC, SATA, and SATA SE arrays.
1.2.1RAID I/O Controller Modules
A
The FC, SATA, and SATA SE array I/O controller modules are
■SANnet II 200 FC array RAID controller modules provide six Fibre Channel ports.
■SANnet II 200 SATA array I/O controller modules provide eight Fibre Channel ports.
■SANnet II 200 SATA SE array I/O controller modules provide six Fibre Channel ports.
Single- and
In the unlikely event of an I/O controller module failure, the redundant RAID controller immediately begins servicing all I/O requests. The failure does not affect application programs.
Each RAID I/O controller module can support up to 1 Gbyte of Synchronous Dynamic Random Access Memory (SDRAM) with Error Control Check (ECC) memory. In addition, each controller supports 64 Mbyte of