Dot Hill Systems II 200 FC service manual 6.3.2 I/O Expansion Module LEDs

Models: II 200 FC

1 210
Download 210 pages 50.54 Kb
Page 106
Image 106
6.3.2I/O Expansion Module LEDs

Note – Ethernet link LEDs on SANnet II 200 FC, SATA, and SATA SE arrays differ from the Ethernet link LEDs found on SANnet II 200 SCSI arrays and SANnet II 220 SCSI arrays. On SANnet II 200 FC, SATA, and SATA SE arrays, a connected port’s Ethernet link LED glows solid amber only on the active controller, because the Ethernet port on an FC array is considered active only if its controller is active. On an inactive controller, a port’s Ethernet link LED is off whether the port is connected or not. The absence of a solid amber light on a connected port’s Ethernet link LED indicates that this controller is not the active controller.

Note – An SFP link status (L) LED is off if there is no connection or a failed connection to this SFP. This does not apply to SATA SE arrays because they do not include SFPs.

6.3.2I/O Expansion Module LEDs

Figure 6-6and Figure 6-7show I/O expansion modules and their LEDs for the SANnet II 200 FC expansion unit and the SANnet II 200 SATA expansion unit.

Note – This does not apply to the SANnet II 200 SATA SE array.

I/O module status

I/O activity

SFP link status

SFP speed

Figure 6-6I/O Expansion Module for a SANnet II 200 FC Expansion Unit

I/O activity

SFP link status

 

I/O module status

SFP speed

Figure 6-7I/O Expansion Module for a SANnet II 200 SATA Expansion Unit

6-8SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual • March 2005

Page 106
Image 106
Dot Hill Systems II 200 FC service manual 6.3.2 I/O Expansion Module LEDs