Using the Analyzer

To Connect to the System Under Test

Transmit Loopback Test Connection

Port 1

Port 2

Tx

Rx

Equipment under test

Transmit loopback is both an interface configuration option and a test connection.

Transmitted data is directed both out of the transmit connector and internally (within the interface pod) to the measurement system.

The analyzer ignores external connections to the receive connector.

For E1 interface pods set for the transmit loopback interface configuration, you can select either the BNC or RJ-48 (equipment, or line connector) as the transmitting connector. For all other interface pods, you can only transmit using the connector labeled Out.

External Loopback Test Connection

Typical applications for this type of connection include calibration, self- testing, troubleshooting, and demonstrations. This is an out-of-service test that runs independently of a network. The analyzer acts as both the transmitter and receiver.