HP Process Resource Manager (PRM) manual Prmlist error messages

Models: Process Resource Manager (PRM)

1 154
Download 154 pages 33.55 Kb
Page 138
Image 138

 

Cause

Options -gand -icannot be used together.

 

Action

Specify either -gor -iand retry prmrun command.

620

Message

%s requires that PRM be configured.

 

Cause

PRM is not configured.

 

Action

Configure PRM with prmconfig -kor -ibefore executing prmrun

 

 

command.

626

Message

Could not find internal configuration file %s.

 

Cause

Could not open internal configuration file %s for reading.

 

Action

Make sure file exists and is readable. Reconfiguring PRM with prmconfig

 

 

-kor -iwill recreate internal file and resync it with /etc/prmconf or the

 

 

specified file.

629

Message

%s has alternate names, do not launch with prmrun.

 

Cause

The prmrun command requires a record with no alternate names for the

 

 

application; it did not find one.

 

Action

Modify the configuration file to contain an application record without alternate

 

 

names, or run the application without using prmrun.

prmlist error messages

803

Message

No Group records in the configuration file.

 

Cause

Could not find any group/CPU records in the internal configuration file.

 

Action

Reconfigure and retry the prmlist command.

805

Message

No User records in the configuration file.

 

Cause

Could not find any user records in the internal configuration file.

 

Action

Add user records as needed.

806

Message

No Compartment records in the configuration file.

 

Cause

Could not find any compartment records in the internal configuration file.

 

Action

Add compartment records as needed.

807

Message

Please specify only one -g option.

 

Cause

More than one -goption was specified on the command line.

 

Action

Specify only one -goption and retry the prmlist command.

808

Message

Please specify only one -u option.

 

Cause

More than one -uoption was specified on the command line.

 

Action

Specify only one -uoption and retry the prmlist command.

809

Message

Please specify only one -a option.

 

Cause

More than one -aoption was specified on the command line.

 

Action

Specify only one -aoption and retry the prmlist command.

810

Message

Please specify only one -d option.

 

Cause

More than one -doption was specified on the command line.

 

Action

Specify only one -doption and retry the prmlist command.

811

Message

Device name %s not legal.

 

Cause

Name given is not a logical volume group.

 

Action

Check the spelling, then use bdf to check whether the device is mounted.

138 PRM error messages

Page 138
Image 138
HP Process Resource Manager (PRM) manual Prmlist error messages