B Server Blade Configuration Examples

This appendix contains illustrations and descriptions of fully cabled HP XC systems based on interconnect type and server blade height.

The connections are color-coded, so consider viewing the PDF file online or printing this appendix on a color printer to take advantage of the color coding.

B.1 Gigabit Ethernet Interconnect With Half-Height Server Blades

In Figure B-1, only the half-height server blades and the non-blade server nodes have connections to the external network. Because the two NICs of the half-height server blade are already in use, an Ethernet card was added to mezzanine bay 1 to allow for the external network connection on the server blade. An interconnect module was added to bay 3.

On the non-blade server nodes, PCI Ethernet NICs are used for the external network connection. Available ports vary based on hardware model. See the HP XC Hardware Preparation Guide for more information about port assignments.

Figure B-1 Gigabit Ethernet Interconnect With Half-Height Server Blades

Ethernet PCI Cards

Non-Blade Server

PCI SLOT

Non-Blade Server

PCI SLOT

MGT

NIC

NIC

PCI SLOT

MGT

NIC

NIC

PCI SLOT

C-Class Blade Enclosure

Admin ProCurve 2800 Series Switch

HALF HEIGHT BLADE FULL HEIGHT BLADE

 

 

 

NIC 1

 

 

 

 

NIC 2

 

 

 

 

NIC 3

 

 

 

 

NIC 4

 

 

 

 

MEZZ 1

 

 

 

 

MEZZ 2

 

Ethernet

 

 

Mezzanine

MEZZ 3

 

 

Card

 

 

 

 

iLO2

 

 

 

 

 

NIC 1

NIC 2

MEZZ 1

MEZZ 2

iLO2

Interconnect bay 1

Interconnect bay 2

Interconnect bay 3

Interconnect bay 4

Interconnect bay 5

Interconnect bay 6

Interconnect bay 7

Interconnect bay 8

ONBOARD

ADMINISTRATOR

Console ProCurve 2600 Series Switch

Gigabit Ethernet Interconnect Switch

External Public Network

KEY

Administration Network

Console Network

Cluster Interconnect Network

External Network

B.2 InfiniBand Interconnect With Full-Height Server Blades

In the configuration shown in Figure B-2, connections to the external network were required only on the non-blade server nodes and the full-height server blades. On those server blades, NIC3 is used for the connection to the external network. A VLAN is used to separate the external network traffic from the administration network traffic on the switch in bay 1 to save the expense of an additional Ethernet interconnect module in bay 2.

On the non-blade server nodes, the built-in NICs were used for the external network connection. Available ports vary based on hardware model. See Chapter 3 (page 45) for more information about port assignments.

B.1 Gigabit Ethernet Interconnect With Half-Height Server Blades 143

Page 143
Image 143
HP XC System Software 3.2.1 Server Blade Configuration Examples, InfiniBand Interconnect With Full-Height Server Blades