1.Make the RBSU settings accordingly for each node. The settings differ depending on the hardware model generation:
•Table
•Table
Table 4-36 RBSU Settings for HP ProLiant DL585 Nodes
Menu Name | Option Name | Set to This Value |
System Options | Embedded Serial Port | Disabled |
| Virtual Serial Port | COM1; IRQ4; |
| Embedded NIC Port 1 PXE | Enabled (all nodes except the head |
| Support | node) |
| Embedded NIC Port 1 PXE | Disabled (head node only) |
| Support |
|
| Power Regulator for ProLiant | Disabled |
Standard Boot Order (IPL) |
| Set the following boot order on all |
|
| nodes except the head node; the |
|
| |
|
| hard drive. |
| IPL1 | |
| IPL2 | Floppy Drive (A:) |
| IPL3 | PCI Embedded HP NC7782 |
|
| Gigabit Server Adapter Port |
|
| 1 |
| IPL4 | Hard Drive (C:) |
|
| On the head node, set the boot order |
|
| so that the |
|
| the hard disk. |
BIOS Serial Console and EMS | BIOS Serial Console Port | COM1; IRQ4; |
| BIOS Serial Console Baud Rate | 115200 |
| EMS Console | Disabled |
| BIOS Interface Mode | Command Line |
Advanced Options | page Directory Cache (PDC) | Disabled |
Table 4-37 lists the RBSU setting for the DL585 G2 nodes.
Table 4-37 RBSU Settings for HP ProLiant DL585 G2 Nodes
Menu Name | Option Name | Set to This Value |
System Options | Embedded Serial Port | Disabled |
| Virtual Serial Port | COM1 |
| Embedded NICs/NIC 1 boot | On all nodes except the head node, set this value |
| Options | to PXE boot |
| Embedded NICs/NIC 2 boot | Disabled (head node only) |
| Options |
|
| Power Regulator for | OS Control Mode |
| ProLiant |
|
4.7 Preparing the Hardware for CP4000 (AMD Opteron) Systems 109