Table 4-24 BIOS Settings for HP ProLiant DL165 G5 Nodes
Menu Name | Submenu Name | Option Name | Set to This Value | |
Main | Boot Settings Configuration | Bootup | Disabled | |
Advanced | I/O Device Configuration | Embedded Serial Port IRQ: | 3F8 | |
|
| Interrupt: | IRQ 4 | |
| ||||
|
| INT13 support | Enabled | |
| Remote Access | Base Address | IRQ [3F8h,4] | |
| Configuration |
|
|
|
|
| Serial Port Mode | 115200 8,n,1 | |
|
| Redirection of BIOS POST | Always | |
|
| Terminal Type | ANSI | |
| IPMI Configuration | LAN Configuration: |
|
|
|
| Share NIC Mode | Disabled | |
|
| DHCP IP Source | Enabled | |
Boot |
|
| Set the following boot order on | |
|
|
| all nodes except the head node: | |
|
|
| 1. | Removable Devices |
|
|
| 2. |
|
|
|
| 3. | MBA v9.0.6 Slot 0820 |
|
|
| 4. | Hard Drive |
|
|
| 5. | MBA v9.0.6 Slot 0821 |
|
|
| Set the following boot order on | |
|
|
| the head node: | |
|
|
| 1. | Removable Devices |
|
|
| 2. |
|
|
|
| 3. | Hard Drive |
4.Select Exit→Saving Changes to exit the BIOS Setup Utility.
5.Repeat this procedure for each HP ProLiant DL165 G5 node in the hardware configuration.
4.7.4Preparing HP ProLiant DL365 Nodes
On HP ProLiant DL365 servers, use the following tools to configure the appropriate settings for an HP XC system:
•Integrated Lights Out (iLO) Setup Utility
•
HP ProLiant DL365 servers use the iLO utility; thus, they need certain settings that you cannot make until the iLO has an IP address. The HP XC System Software Installation Guide provides instructions for using a browser to connect to the iLO to enable telnet access.