13.Perform this step on all nodes except the head node. From the Boot Configuration menu, select the Edit OS Boot Order option.

Do the following:

a.Use the navigation instructions on the screen to move the Netboot entry you just defined to the top of the boot order.

b.If prompted, press the Enter key to select the position.

c.Enter x to return to the Boot Configuration menu.

14.Perform this step on all nodes, including the head node.

Select the Console Configuration option, and do the following:

a.Enable the Serial Acpi(HWP0002,PNP0A03,700)/Pci(11) Vt100+ 9600 option.

b.Press the Esc key or enter x as many times as necessary to return to the Boot Configuration menu.

c.When prompted, save the entry to NVRAM.

15.Turn off power to the node:

a.Press Ctrl-Bto exit the console mode.

b.Enter CM to display the Command Menu.

c.Enter PC and enter off to turn off power to the node.

4.9.4Preparing HP Integrity rx2660 Nodes

Figure 4-29shows a rear view of the HP Integrity rx2660 server and the appropriate port assignments for an HP XC system.

Figure 4-29 HP Integrity rx2660 Server Rear View

1

2

3

The callouts in the figure enumerate the following:

1.The LAN port labeled Gb 1 connects to the Administration Switch (branch or root).

2.The LAN port labeled Gb 2 is used for an external connection.

3.The port labeled MP LAN is the MP connection to the ProCurve Console Switch.

Setup Procedure

Perform the following procedure on each HP Integrity rx2660 server:

1.Use the instructions in the accompanying hardware documentation to connect a monitor, mouse, and keyboard to the node.

2.For each node in the system, ensure that the power cord is connected but that the processor is not turned on.

3.Follow this procedure to connect a personal computer to the Management Processor (MP):

a.Connect a cable to the console port (located to the left of the MP LAN port) on the back of the HP Integrity rx2660 server.

4.9 Preparing the Hardware for CP6000 (Intel Itanium) Systems 127