Configuring Smart Arrays

On the HP ProLiant DL360 G5 nodes with smart array cards, you must add the disks to the smart array before attempting to image the node.

To do so, watch the screen carefully during the power-on self-test phase of the node, and press the F8 key when prompted to configure the disks into the smart array.

Specific instructions are outside the scope of the HP XC documentation. See the documentation that came with the HP ProLiant server for more information.

4.5.5 Preparing HP ProLiant DL380 G4 and G5 Nodes

Use the following tools to configure the appropriate settings on HP ProLiant DL380 G4 and G5 servers:

Integrated Lights Out (iLO) Setup Utility

ROM-Based Setup Utility (RBSU)

HP ProLiant DL380 G4 and G5 servers use the iLO utility; thus, they need certain settings that you cannot make until the iLO has an IP address. The HP XC System Software Installation Guide provides instructions for using a browser to connect to the iLO to enable telnet access.

Figure 4-5shows a rear view of the HP ProLiant DL380 G4 server and the appropriate port assignments for an HP XC system.

Figure 4-5 HP ProLiant DL380 G4 Server Rear View

3

2

PCI-X PCI-E

32

100 x4 MHz

21

100 x4 MHz

iLO

1

133N/A

MHz

2 1

SCSI Port 1

UID

The callouts in the figure enumerate the following:

1.The iLO Ethernet port is used for the connection to the Console Switch.

2.NIC2 is used for the connection to the external network.

3.NIC1 is used for the connection to the Administration Switch (branch or root).

Figure 4-6shows a rear view of the HP ProLiant DL380 G5 server and the appropriate port assignments for an HP XC system.

72 Preparing Individual Nodes