The callouts in the figure enumerate the following:

1.This port is used for the connection to the Console Switch. On the back of the node, this port is marked with LO100i.

2.This port is used for the connection to the Administration Switch (branch or root). On the back of the node, this port is marked with the number 1 (NIC1).

3.If a Gigabit Ethernet (GigE) interconnect is configured, this port is used for the interconnect connection. Otherwise, it is used for an external connection. On the back of the node, this port is marked with the number 2 (NIC2).

Setup Procedure

Perform the following procedure for each HP ProLiant DL160 G5 node in the hardware configuration. Change only the values described in this procedure; do not change any other factory-set values unless you are instructed to do so. Follow all steps in the sequence shown:

1.Use the instructions in the accompanying HP ProLiant hardware documentation to connect a monitor, mouse, and keyboard to the node.

2.Turn on power to the node. Watch the screen carefully during the power-on, self-test, and press the F10 key when prompted to access the BIOS Setup Utility. The Lights-Out 100i (LO-100i) console management device is configured through the BIOS Setup Utility.

The BIOS Setup Utility displays the following information about the node:

BIOS ROM ID: BIOS Version: BIOS Build Date:

Record this information for future reference.

3.For each node, make the following BIOS settings from the Main window. The BIOS settings for HP ProLiant DL160 G5 nodes are listed in Table 4-5.

Table 4-5 BIOS Settings for HP ProLiant DL160 G5 Nodes

Menu Name

Submenu Name

Option Name

Set to This Value

Main

Boot Features

Numlock

Disabled

Advanced

 

8042 Emulation

Disabled

 

 

Support

 

 

Remote Access

Remote Access

Enabled

 

Configuration

 

 

 

 

EMS Support

Enabled

 

 

(SPCR)

 

 

 

Serial Port Mode

11520 8,n,1

 

 

Redirection after

Always

 

 

BIOS POST

 

 

 

Terminal Type

VT100

 

IPMI Configuration

LAN Configuration

 

 

 

Share NIC Mode

Disabled

 

 

DHCP IP Source

Enabled

Boot

Boot Device Priority

1st Boot Device

If this node is the head node, set this

 

 

 

value to:

 

 

 

Hard Drive

 

 

 

For all other nodes, set this value to:

 

 

 

Embedded NIC1

4.5 Preparing the Hardware for CP3000 (Intel Xeon with EM64T) Systems 67

Page 67
Image 67
HP XC System Software 3.2.1 manual Bios Settings for HP ProLiant DL160 G5 Nodes, Value to