Figure 4-7 HP ProLiant DL580 G4 Server Rear View

1

2

3

The callouts in the figure enumerate the following:

1.NIC1 is used for the connection to the Administration Switch (branch or root).

2.NIC2 is used for the connection to the external network.

3.The iLO Ethernet port is used for the connection to the Console Switch.

Setup Procedure

Perform the following procedure from the iLO Setup Utility for each HP ProLiant DL580 G4 node in the HP XC system:

1.Use the instructions in the accompanying HP ProLiant hardware documentation to connect a monitor, mouse, and keyboard to the node.

2.Turn on power to the node. Watch the screen carefully during the power-on self-test, and press the F8 key when prompted to access the Integrated Lights Out Setup Utility.

3.Make the iLO settings listed in Table 4-13for each node in the hardware configuration.

76 Preparing Individual Nodes