Table 4-37 RBSU Settings for HP ProLiant DL585 G2 Nodes (continued)

Menu Name

Option Name

Set to This Value

Standard Boot Order (IPL)

 

Set the following boot order on all nodes except

 

 

the head node; the CD-ROM must be listed before

 

 

the hard drive:

 

 

IPL:1 CD-ROM

 

 

IPL:2 Floppy Drive (A:)

 

 

IPL:3 USB Drive Key (C:)

 

 

IPL:4 PCI Embedded HP NC373i

 

 

 

Multifunction Gigabit Adapter

 

 

IPL:5 Hard Drive C:

 

 

Set the following boot order on the head node:

 

 

IPL:1 CD-ROM

 

 

IPL:2 Floppy Drive (A:)

 

 

IPL:3 USB Drive Key (C:)

 

 

IPL:4 Hard Drive C:

 

 

 

BIOS Serial Console and

BIOS Serial Console Port

COM1

EMS

 

 

 

 

BIOS Serial Console Baud

115200

 

Rate

 

 

 

EMS Console

Disabled

 

BIOS Interface Mode

Command Line

 

 

 

Advanced

Linux x86_64 HPET Option

Enabled

 

 

 

 

2.Press the Esc key to exit the RBSU. Press the F10 key to confirm your choice and restart the boot sequence.

3.Repeat this procedure for each node HP ProLiant DL585 G2 node in the hardware configuration.

Configuring Smart Arrays

On such hardware models as the HP ProLiant DL585 and DL585 G2 with smart array cards, you must add the disks to the smart array before attempting to image the node.

To do so, watch the screen carefully during the power-on self-test phase of the node, and press the F8 key when prompted to configure the disks into the smart array.

Specific instructions are outside the scope of the HP XC documentation. See the documentation that came with the HP ProLiant server for more information.

4.7.9 Preparing HP ProLiant DL585 G5 Nodes

On HP ProLiant DL585 G5 servers, use the following tools to configure the appropriate settings for an HP XC system:

Integrated Lights Out (iLO) Setup Utility

ROM-Based Setup Utility (RBSU)

HP ProLiant DL585 G5 servers use the iLO utility; thus, they need certain settings that you cannot make until the iLO has an IP address. The HP XC System Software Installation Guide provides instructions for using a browser to connect to the iLO to enable telnet access.

Figure 4-22shows a rear view of the HP ProLiant DL585 G5 server and the appropriate port assignments for an HP XC system.

110 Preparing Individual Nodes