Table 4-3 BIOS Settings for HP ProLiant DL140 G2 Nodes (continued)
Menu Name | Submenu Name | Option Name | Set to This Value | |
|
| Wake On LAN | Disabled | |
Boot |
|
| Set the following boot order on all nodes | |
|
|
| except the head node: | |
|
|
| 1. | |
|
|
| 2. | Removable Devices |
|
|
| 3. | PXE MBA V7.7.2 Slot 0200 |
|
|
| 4. | Hard Drive |
|
|
| 5. | ! PXE MBA V7.7.2 Slot 0300 (! |
|
|
|
| means disabled) |
|
|
| Set the following boot order on the head | |
|
|
| node: | |
|
|
| 1. | |
|
|
| 2. | Removable Devices |
|
|
| 3. | Hard Drive |
|
|
| 4. | PXE MBA v7.7.2 SLot 0200 |
|
|
| 5. | PXE MBA v7.7.2 SLot 0300 |
Table 4-4 lists the BIOS settings for HP ProLiant DL140 G3 nodes.
Table 4-4 BIOS Settings for HP ProLiant DL140 G3 Nodes
Menu Name | Submenu Name | Option Name | Set to This Value | |
Main | Boot Features | Numlock | Disabled | |
Advanced |
| 8042 Emulation | Disabled | |
|
| Support |
|
|
| I/O Device | Serial Port | BMC | |
| Configuration |
|
|
|
| Console Redirection | Console Redirection | Enabled | |
|
| EMS Console | Enabled | |
|
| Baud Rate | 115.2K | |
|
| Continue C.R. after | Enabled | |
|
| POST |
|
|
| IPMI/LAN Settings | IP Address | DHCP | |
|
| Assignment |
|
|
|
| BMC Telnet Service | Enabled | |
|
| BMC Ping Response | Enabled | |
|
| BMC HTTP Service | Enabled | |
|
| BMC HTTPS Service | Enabled | |
Boot |
|
| Set the following boot order on the head | |
|
|
| node: | |
|
|
| 1. | |
|
|
| 2. | Removable Devices |
|
|
| 3. | Hard Drive |
|
|
| 4. | Embedded NIC1 |
|
|
| 5. | Embedded NIC2 |
4.5 Preparing the Hardware for CP3000 (Intel Xeon with EM64T) Systems 65