Step 2. Loading the Diagnostics
1. Stop all application programs running on the operating system.
2. Stop the operating system.
3. Turn the power off.
4. If you are loading the Standalone Diagnostics and running them from an ASCII
terminal, do the following:
The attributes for the terminal must be set to match the defaults of the
diagnostics.
If you need to change any settings, record the normal settings, and be sure
the terminal attributes are set to work with the diagnostics. If needed, see
“Running the Diagnostics from a TTY Terminal” on page 5-3.
Proceed to substep 5 when you finish checking the attributes.
5. Turn the power on.
a. When the Keyboard indicator appears, press the 5 key on the keyboard to
load the Standalone Diagnostics or press the 6 key to load the Online
Diagnostics.
b. Enter any requested passwords.
c. Follow the instructions to select a console.
6. When the Diagnostic Operating Instructions display, go to “Step 3. Running
System Verification” on page 7-3. If you are unable to load the diagnostics, go
to “Problem Determination When Unable to Load Diagnostics” on page 8-11.