Step 2. Loading the Diagnostics

1. Stop all application programs running on the operating system.

2.Stop the operating system.

3.Turn the power off.

4.If you are loading the Standalone Diagnostics and running them from an ASCII

terminal, do the following:

ŸThe attributes for the terminal must be set to match the defaults of the diagnostics.

Ÿ If

you need to change any

settings, record

the normal settings, and be sure

the

terminal

attributes

are

set

to work with

the diagnostics. If needed, see

“Running the

Diagnostics

from

a TTY

Terminal” on

page 5-3.

Ÿ Proceed to substep 5 when you finish checking the attributes.

5. Turn the power on.

a. When theKeyboard indicator appears, press the 5 key on the keyboard to load the Standalone Diagnostics or press the 6 key to load the Online Diagnostics.

b. Enter any requested passwords.

c. Follow the instructions to select a console.

6. When

the

Diagnostic

Operating

Instructions

display, go

to

“Step 3.

Running

System

Verification”

on

page 7-3. If

you

are

unable

to

load

the

diagnostics, go

to “Problem

Determination

When

Unable

to Load

Diagnostics”

on

page 8-11.